Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Anal Chem ; 94(14): 5715-5722, 2022 04 12.
Article in English | MEDLINE | ID: covidwho-1773910

ABSTRACT

Nanopipettes provide a promising confined space that enables advances in single-molecule analysis, and their unique conical tubular structure is also suitable for single-cell analysis. In this work, functionalized-nanopore-based single-entity electrochemistry (SEE) analysis tools were developed for the label-free monitoring of single-molecule glycoprotein-boronate affinity interaction for the first time, and immunoglobulin G (IgG, one of the important biomarkers for many diseases such as COVID-19 and cancers) was employed as the model glycoprotein. The principle of this method is based on a single glycoprotein molecule passing through 4-mercaptophenylboronic acid (4-MPBA)-modified nanopipettes under a bias voltage and in the meantime interacting with the boronate group from modified 4-MPBA. This translocation and affinity interaction process can generate distinguishable current blockade signals. Based on the statistical analysis of these signals, the equilibrium association constant (κa) of single-molecule glycoprotein-boronate affinity interaction was obtained. The results show that the κa of IgG in the confined nanopore at the single-molecule level is much larger than that measured in the open system at the ensemble level, which is possibly due to the enhanced multivalent synergistic binding in the restricted space. Moreover, the functionalized-nanopore-based SEE analysis tools were further applied for the label-free detection of IgG, and the results indicate that our method has potential application value for the detection of glycoproteins in real samples, which also paves way for the single-cell analysis of glycoproteins.


Subject(s)
Electrochemistry , Nanopores , Electrochemistry/methods , Glycoproteins/chemistry , Humans , Immunoglobulin G
2.
Mikrochim Acta ; 188(12): 434, 2021 11 27.
Article in English | MEDLINE | ID: covidwho-1536308

ABSTRACT

A novel and sensitive voltammetric nanosensor was developed for the first time for trace level monitoring of favipiravir based on gold/silver core-shell nanoparticles (Au@Ag CSNPs) with conductive polymer poly (3,4-ethylene dioxythiophene) polystyrene sulfonate (PEDOT:PSS) and functionalized multi carbon nanotubes (F-MWCNTs) on a glassy carbon electrode (GCE). The formation of Au@Ag CSNPs/PEDOT:PSS/F-MWCNT composite was confirmed by various analytical techniques, including X-ray diffraction (XRD), ultraviolet-visible spectroscopy (UV-Vis), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), and field-emission scanning electron microscopy (SEM). Under the optimized conditions and at a typical working potential of + 1.23 V (vs. Ag/AgCl), the Au@Ag CSNPs/PEDOT:PSS/F-MWCNT/GCE revealed linear quantitative ranges from 0.005 to 0.009 and 0.009 to 1.95 µM with a limit of detection 0.46 nM (S/N = 3) with acceptable relative standard deviations (1.1-4.9 %) for pharmaceutical formulations, urine, and human plasma samples without applying any sample pretreatment (1.12-4.93%). The interference effect of antiviral drugs, biological compounds, and amino acids was negligible, and the sensing system demonstrated outstanding reproducibility, repeatability, stability, and reusability. The findings revealed that this assay strategy has promising applications in diagnosing FAV in clinical samples, which could be attributed to the large surface area on active sites and high conductivity of bimetallic nanocomposite.


Subject(s)
Amides/pharmacology , Antiviral Agents/pharmacology , COVID-19 Drug Treatment , Electrochemistry/methods , Metal Nanoparticles/chemistry , Nanocomposites/chemistry , Nanomedicine/methods , Nanotechnology/methods , Pyrazines/pharmacology , Colloids/chemistry , Electrodes , Gold/chemistry , Humans , Limit of Detection , Linear Models , Nanotubes , Polymers/chemistry
3.
Sci Rep ; 11(1): 21768, 2021 11 05.
Article in English | MEDLINE | ID: covidwho-1505016

ABSTRACT

Rapid design, screening, and characterization of biorecognition elements (BREs) is essential for the development of diagnostic tests and antiviral therapeutics needed to combat the spread of viruses such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To address this need, we developed a high-throughput pipeline combining in silico design of a peptide library specific for SARS-CoV-2 spike (S) protein and microarray screening to identify binding sequences. Our optimized microarray platform allowed the simultaneous screening of ~ 2.5 k peptides and rapid identification of binding sequences resulting in selection of four peptides with nanomolar affinity to the SARS-CoV-2 S protein. Finally, we demonstrated the successful integration of one of the top peptides into an electrochemical sensor with a clinically relevant limit of detection for S protein in spiked saliva. Our results demonstrate the utility of this novel pipeline for the selection of peptide BREs in response to the SARS-CoV-2 pandemic, and the broader application of such a platform in response to future viral threats.


Subject(s)
COVID-19/immunology , Combinatorial Chemistry Techniques , Peptides/chemistry , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/chemistry , COVID-19/virology , Computational Biology , Electrochemistry/methods , Enzyme-Linked Immunosorbent Assay , Humans , Interferometry , Kinetics , Peptide Library , Protein Array Analysis , Protein Engineering , Saliva/immunology
4.
Sci Rep ; 11(1): 21723, 2021 11 05.
Article in English | MEDLINE | ID: covidwho-1503978

ABSTRACT

Coronavirus with intact infectivity attached to PPE surfaces pose significant threat to the spread of COVID-19. We tested the hypothesis that an electroceutical fabric, generating weak potential difference of 0.5 V, disrupts the infectivity of coronavirus upon contact by destabilizing the electrokinetic properties of the virion. Porcine respiratory coronavirus AR310 particles (105) were placed in direct contact with the fabric for 1 or 5 min. Following one minute of contact, zeta potential of the porcine coronavirus was significantly lowered indicating destabilization of its electrokinetic properties. Size-distribution plot showed appearance of aggregation of the virus. Testing of the cytopathic effects of the virus showed eradication of infectivity as quantitatively assessed by PI-calcein and MTT cell viability tests. This work provides the rationale to consider the studied electroceutical fabric, or other materials with comparable property, as material of choice for the development of PPE in the fight against COVID-19.


Subject(s)
COVID-19/prevention & control , COVID-19/transmission , Electrochemistry/methods , Textiles , Animals , Anti-Infective Agents , Body Fluids , Cell Line , Cell Survival , Fluoresceins , Humans , Hydrogen Peroxide , Kinetics , Nanoparticles , Propidium , SARS-CoV-2 , Swine , Temperature , Tetrazolium Salts , Thiazoles , Virion , Wound Healing
5.
Molecules ; 26(11)2021 May 28.
Article in English | MEDLINE | ID: covidwho-1320599

ABSTRACT

Deferoxamine B is an outstanding molecule which has been widely studied in the past decade for its ability to bind iron and many other metal ions. The versatility of this metal chelator makes it suitable for a number of medicinal and analytical applications, from the well-known iron chelation therapy to the most recent use in sensor devices. The three bidentate hydroxamic functional groups of deferoxamine B are the centerpiece of its metal binding ability, which allows the formation of stable complexes with many transition, lanthanoid and actinoid metal ions. In addition to the ferric ion, in fact, more than 20 different metal complexes of deferoxamine b have been characterized in terms of their chemical speciation in solution. In addition, the availability of a terminal amino group, most often not involved in complexation, opens the way to deferoxamine B modification and functionalization. This review aims to collect and summarize the available data concerning the complex-formation equilibria in solutions of deferoxamine B with different metal ions. A general overview of the progress of its applications over the past decade is also discussed, including the treatment of iron overload-associated diseases, its clinical use against cancer and neurodegenerative disorders and its role as a diagnostic tool.


Subject(s)
Chelating Agents/chemistry , Deferoxamine/chemistry , Animals , Antineoplastic Agents/pharmacology , Chelating Agents/pharmacology , Chemistry, Pharmaceutical/methods , Electrochemistry/methods , Electrolytes , Humans , Hydrogen-Ion Concentration , Ions , Iron/metabolism , Iron Chelating Agents/chemistry , Iron Overload/drug therapy , Kinetics , Ligands , Metals/chemistry , Neoplasms/drug therapy , Potentiometry , SARS-CoV-2 , Temperature , Zirconium/chemistry , COVID-19 Drug Treatment
6.
J Clin Virol ; 137: 104784, 2021 04.
Article in English | MEDLINE | ID: covidwho-1122967

ABSTRACT

BACKGROUND: Accurate anti-SARS-CoV-2 assays are needed to inform diagnostic, therapeutic, and public health decisions. The first manufacturer-independent head-to-head comparison of two rapid high-throughput automated electrochemiluminescence double-antigen sandwich immunoassays targeting total anti-SARS-CoV-2 antibodies against two different viral proteins, Elecsys Anti-SARS-CoV-2 (Elecsys-N) and Elecsys Anti-SARS-CoV-2 S (Elecsys-S) (Roche Diagnostics), was performed in a routine setting during the exponential growth phase of the epidemic's second wave. METHODS: The diagnostic specificity of Elecsys-N and Elecsys-S was initially evaluated on a panel of 572 pre-COVID-19 samples, showing 100 % specificity of both assays. Elecsys-N/Elecsys-S head-to-head comparison used 3,416 consecutive blood samples from individuals that were tested for the presence of anti-SARS-CoV-2 within commercial out-of-pocket serologic testing. RESULTS: Elecsys-N/Elecsys-S head-to-head comparison showed overall agreement of 98.68 % (3,371/3,416; 95 % CI, 98.23-99.03 %), positive agreement of 95.16 % (884/929; 95 % CI, 93.52-96.41 %), and a high kappa value of 0.996 (95 % CI, 0.956-0.976). Previous SARS-CoV-2 PCR positivity was identified in 14/24 (58.3 %) Elecsys-N negative/Elecsys-S positive individuals and in 4/21 (19.0 %) Elecsys-N positive/Elecsys-S negative individuals. CONCLUSION: The first Elecsys-N/Elecsys-S head-to-head comparison showed excellent agreement of two highly specific and rapid high-throughput automated anti-SARS-CoV-2 assays. An important question is whether laboratories offering two different antibody assays could benefit from combining the assays; if so, should use be concomitant or sequential-and, in the latter case, in which order? Based on our results, we favor concomitant over sequential Elecsys-N/Elecsys-S use when testing individuals for anti-SARS-CoV-2 antibodies in high-incidence settings; for example, during the exponential or stationary growth phase of the COVID-19 epidemic.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , High-Throughput Screening Assays/methods , Nucleoproteins/immunology , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , COVID-19/blood , Electrochemistry/methods , Humans , Immunoassay/methods , Immunoglobulin G/blood , SARS-CoV-2/isolation & purification , Sensitivity and Specificity